PL380 

PowerLight 3 Series is comprised of our “Ultimate Analog” power house amplifier, designed for the most demanding concert and live-sound reinforcement applications. The PL380 features the ground breaking PowerLight™ power supply technology, dramatically reducing weight, eliminating AC mains hum and improving audio quality. Comprehensive remote control and monitoring can also be achieved via the Q-SYS networked platform.

  • Class D topology provides efficient performance at extreme power loads
  • Three-position Input Sensitivity switch ensures gain-matching with existing amp racks and power systems
  • User defeatable clip limiters and selectable low-frequency filters (30 Hz, 50 Hz, Bypass)
  • DataPort connection supports external amplifier control and monitoring via Q-SYS
  • XLR and Block Input connectors and Binding post or Neutrik speakON® Output connectors
  • Comprehensive internal protection protects amplifiers and loudspeakers against over-current, over-temperature and clipping – without compromising program signal
Categories: , ,

Description

Features

  • PowerLight switch-mode power supply for highest efficiency and improved audio performance
  • Flow-through air path and solid aluminum heat sinks for maximum cooling
  • DataPort supports remote network control and monitoring via Q-SYS
  • Detented gain controls with 1-dB steps for precise calibration
  • Removable knobs with lock-out security plate to prevent unauthorized tampering
  • User defeatable clip limiters and selectable low-frequency filter per channel (3 Hz, 30 Hz, or 50 Hz)
  • Three selectable gain structures (26 dB, 32 dB, or 1.2 V)
  • Front and rear panel LEDs indicate status of switch settings at a glance
  • Parallel XLR/M and XLR/F connectors for simple loop-through connectivity
  • Neutrik Speakon® and “Touch-Proof” binding post outputs
  • Neutrik Powercon® power cable remains secure on the road
  • 3 year warranty, plus optional 3 year extended service contract
  • Linear Class H output circuit offer double the typical efficiency of Class B, reducing AC current consumption and cooling requirements

 

SPECIFICATIONS PL380
OUTPUT POWER PER CHANNEL, STERO MODE, both channels driven
8Ω EIA 1 kHz 1% THD 1500 W
4Ω EIA 1 kHz 1% THD 2500 W
2Ω EIA 1 kHz 1% THD 4000 W*
OUTPUT POWER, BRIDGE MONO MODE
8Ω EIA 1 kHz 1% THD 5000 W
4Ω EIA 1 kHz 1% THD 8000 W*
Typical Distortion
(20 Hz–3 kHz, 3 dB below clip, or 20 Hz–5 kHz, 10 dB below clip, or 20 Hz–20 kHz, 20 dB below clip)
8 ohms
4 ohms
2 ohms

0.01-0.03%
0.03-0.06%
0.1%

Maximum Distortion
(20 Hz–20 kHz, 1 dB below rated power)
4 to 8 ohms

0.2%

Frequency Response (8 ohms) 20 Hz–20 kHz, ±0.2 dB
Noise (20 Hz–20 kHz, 32 dB Gain) -104 dB
Dynamic Headroom (4 ohms) 2 dB
Damping Factor (8 ohms) 200
Output Circuitry Class D
Input Sensitivity
26 dB Setting
32 dB Setting
5.27V
2.67V
Maximum Gain (1.2V setting) 39.1 dB
Maximum Input Level
1.2V setting
32 dBu setting
26 dBu setting
10 V (+22 dBu)
22 V (+29 dBu)
25 V (+30 dBu)
AC Power Requirements **
120V 50/60 Hz
230V 50 Hz
18 A
11 A
Cordset
120V 50/60 Hz
230V 50 Hz
NEMA L5-30P
CEE 7/7 16A
Chassis Power Connector
All Voltages
32A PowerCon
Input Impedance > 10 kΩ balanced, or unbalanced
Cooling Variable-speed fan, rear-to-front air flow
Connectors (each channel) Input: XLR Male, XLR Female and 3-pin detachable terminal blocks (1 each per channel)
Output: Neutrik Speakon® (ch 1 wired to both channels) and 5-way binding posts
DataPort: HD-15, input signal in parallel with XLR input connectors
Front Controls AC power switch
Gain controls, 21 detents, 1 dB steps (each channel)
Front Indicators (LED color) Power (Blue)
Bridged (Yellow)
Parallel (Orange)
Clip/Prot (Red × 2)
Level -10 (Orange × 2)
Level -20 (Green × 2)
Signal -35 (Green × 2)
Rear Controls (with LED indicators) Input Mode: Bridge (Yellow), Stereo (Green), or Parallel (Orange)
Gain / Sensitivity: 26 dB (Orange), 32 dB (Green), or 1.2V (Yellow)
High Pass (each channel): 3 Hz (Off), 30 Hz (Yellow), or 50 Hz (Orange)
Clip Limiter (each channel): Off, on (Yellow)
Amplifier and Load Protection Short circuit, open circuit, thermal, RF protection. On/off muting, DC fault shutdown, active inrush limiting
Product Dimensions (H×W×D) 89 (2 RU) × 483 × 397 mm
3.5 (2 RU) × 19 × 15.63 in
Carton Dimensions (H×W×D) 610 × 560 × 178 mm
24 × 22 × 7 in
Net Weight 11 kg / 24 lb
Shipping Weight 15.0 kg / 33 lb
Agency Approvals UL, CE, RoHS/WEEE compliant, FCC Class B (conducted and radiated emissions)